Ethernet Protection Solutions to Surge Test Standards
2020-08-13
Application background
1. Global warming, more thunderstorms
2. After the power supply is damaged by lightning, it is very harmful
3. After the power supply is damaged by lightning, the maintenance cost is high
4. High surge protective equipment becomes an industry trend
Socay Electronics Components
Gas Discharge Tubes(GDTs)
GDT【SC1206-200ASMD】DC Spark-over Voltage:200±30%V,Nominal Impulse Discharge Current(8/20μS):0.5kA,Maximum Capacitance<0.5pF,Minimum Insulation Resistance >100MΩ;
GDT【SC1812-90CSMD】DC Spark-over Voltage:90±20%V,Nominal Impulse Discharge Current(8/20μS):2.0kA,Maximum Capacitance<1.0pF,Minimum Insulation Resistance >1GΩ
TVS diode
TVS【ESD03V32D-LC】Vrwm:3.0V;Vb:4.0V;Vesd:8KV/15KV;Ct(f=1MHz):1.2pF;Package: SOD-323
Application
Application
1. Laptop, PAD, home desktop computer, industrial computer
2.Switches/Router
3.camera equipment
4. Network printer
5. Set-top box
6. intelligent transportation system
7.Other devices with Ethernet ports
The Solution Note
1. The solution uses GDT in the front end of the transformer to do common mode (eight lines) surge protection.
2.The back end of the network transformer uses TVs with small volume and low junction capacitance to absorb differential mode energy. The TVS has fast reaction time and takes into account the function of electrostatic protection.
3. Comply with 802.11 electrical standards.
4. Meet IEC61000-4-5, GBT17626.5 and other surge test standards.
5. Meet IEC61000-4-2, GBT17626.2 and other electrostatic test standards.